Folding Systems
Technical informationMetric
Imperial
Performance
Insulation
- Thermal insulation (Best) - Uf
- 1.7 W/m²K 0.30 Btu/hr·ft²·°F
- Thermal insulation - Uw
- 1.4 W/m²K 0.25 Btu/hr·ft²·°F
- Uw Dependencies
- Ug 1.0W/m²K, warm edge spacer, @3.00x2.30m, 24mm glass Ug 0.18 Btu/hr·ft²·°F, warm edge spacer, @3.00x2.30m, 24mm glass
Comfort
- Air tightness
- Class 4 (600Pa) Class 4 (600Pa)
- Water tightness
- Class 9A (600Pa) Class 9A (600Pa)
- Wind load resistance
- Class B3 (1200Pa) Class B3 (1200Pa)
- Acoustics - Rw(C;Ctr)
- 40(-2;-4) dB 40(-2;-4) dB
- Durability
- Class 3 (20000 cycles) Class 3 (20000 cycles)
Safety & Security
- Burglar resistance
- PAS 24 PAS 24 - RC2 RC2
- Impact resistance
- I4 I4
Properties
Max. dimensions & weight
- Min. height of vent
- 800 mm 31.5 in
- Max. height of vent
- 2500 mm 98.4 in
- Min. width of vent
- 400 mm 15.75 in
- Max. width of vent
- 1200 mm 47.25 in
- Max. weight of vent
- 120 kg 264.55 lbs
Sightlines
- Min. width meeting section
- 131 mm 5.16 in
- Min. width transom profile
- 30 mm 1.18 in
- Min. height threshold
- 5 mm 0.2 in
- Depth frame
- 68 mm 2.68 in
- Depth Vent
- 68 mm 2.68 in
- Depth frame-vent
- 68 mm 2.68 in
Glazing
- Rebate height
- 25 mm 0.98 in
- Glazing method
- Dry glazing Dry glazing - Siliconized glazing Siliconized glazing - Internal glazing Internal glazing - Glazing bead Glazing bead
- Min. glass thickness - vent
- 12 mm 0.47 in
- Max. glass thickness - vent
- 55 mm 2.17 in