Performance
Insulation
- Thermal insulation - Uw
- 0.8 W/m²K 0.14 Btu/(h·ft²·°F)
- Uw Dependencies
- Ug 0.6W/m²K, warm edge spacer, @4.50x2.30m, 36mm glass Ug 0.11 Btu/(h·ft²·°F), warm edge spacer, @14.76x7.55 ft, 1.42 in glass
Comfort
- Air tightness
- Class 4 (600Pa) Class 4 (0.087 psi)
- Water tightness
- Class E1200 (1200Pa) Class E1200 (0.174 psi)
- Wind load resistance
- Class C5 (2000Pa) Class C5 (0.29 psi)
- Acoustics - Rw(C;Ctr)
- 44(-1;-4) dB
- Durability
- Class 4 (50000 cycles)
Safety & Security
- Burglar resistance
- PAS 24 - RC2
- Impact resistance
- I4
Properties
Max. dimensions & weight
- Min. height of vent
- 1800 mm 70.87 in
- Max. height of vent
- 3600 mm 141.73 in
- Min. width of vent
- 700 mm 27.56 in
- Max. width of vent
- 3000 mm 118.11 in
- Max. weight of vent
- 500 kg 1102.31 lb
- Max. weight of fixed vent
- 1200 kg 2645.55 lb
Sightlines
- Min. width central closer
- 181 mm 7.13 in
- Min. width meeting section
- 50 mm 1.97 in
- Min. width transom profile
- 50 mm 1.97 in
- Min. height threshold
- 4 mm 0.16 in
- Depth Vent
- 77 mm 3.03 in
- Depth frame-vent
- 180 mm 7.09 in
- Depth frame monorail
- 180 mm 7.09 in
- Depth frame 2-rail
- 180 mm 7.09 in
- Depth frame 3-rail
- 283 mm 11.14 in
Glazing
- Rebate height
- 27 mm 1.06 in
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
- Min. glass thickness - vent
- 16 mm 0.63 in
- Max. glass thickness - vent
- 62 mm 2.44 in